SEWAGE PUMPING STATION OPERATION PRINCIPLE

1. The pumping station is an automatic facility. Incoming sewage is collected in the pumping tank until the maximum level is reached. Once the maximum level is exceeded, a pulse from the level sensor activates the pump. The pump pumps the accumulated sewage until the minimum level is reached, after which the pump is turned off and the cycle can begin again. PUMPING STATION CONSTRUCTION

2. The pumping tanks are made of HDPE (high-density polyethylene). The pumping stations are equipped (depending on the selected model) with discharge pipelines with shut-off and non-return valves, a tight transition through the walls of the gravity and discharge pipelines, and an optional additional control system. Ball check valves installed on the discharge risers prevent wastewater backflow, while shut-off valves allow for shut-off for maintenance purposes. LIQUID LEVEL CONTROL

3. In the basic version of the pumping station, the following wastewater levels are used in the control system: - Maximum level - pump activation, - Minimum level - pump deactivation. Accessories such as the SAFEMATIC electronic pump protection, the E1/E2 Set control box for electric pumps, and the Pedrollo EP electronic pump protection can be ordered for this pumping station.

IMPORTANT! Upon receipt of the goods, the Buyer is obligated to inspect the goods for quality and quantity and to report any concerns regarding the goods visible on the day of delivery, under penalty of forfeiture of subsequent warranty claims. If the goods are delivered by an external courier company, the Buyer should inspect the goods and immediately report any damage to the carrier before delivery. If, after delivery, the Buyer discovers any loss or damage to the goods that was not visible from the outside upon receipt, they should report this to the carrier and the Seller immediately after discovering the damage, but no later than 7 days from the date of delivery.

1

This product is available by order only.

Sewage pumping stations are complete systems designed for hydraulically transporting sanitary, industrial, combined sewer, and stormwater wastewater to a selected collection point. Pumping stations are particularly important when the receiving water level is higher than the incoming sewage.

It is recommended to use the instructions for installing the pumping station, which are available for download in PDF format.

Tank Features:

  • Tank Height: 2070 mm
  • Diameter: 620 mm
  • Ring Diameter: 670 mm
  • Cover Diameter: 595 mm
  • Capacity: 600 liters

VX 10/50 Pump Parameters:

  • Power Supply: 230V Pump Power
  • 0.75 kW Maximum
  • Capacity: 550 liters per minute Headroom
  • Height: 9.5 m
  • Rated Current: 5.5 A
  • Discharge Connection: 2" GW
  • Passage: 50 mm
  • Weight: 15.7 kg

SEWAGE PUMPING STATION OPERATION PRINCIPLE

1. The pumping station is an automatic facility. Incoming sewage is collected in the pumping tank until the maximum level is reached. Once the maximum level is exceeded, a pulse from the level sensor activates the pump. The pump pumps the accumulated sewage until the minimum level is reached, after which the pump is turned off and the cycle can begin again. PUMPING STATION CONSTRUCTION

2. The pumping tanks are made of HDPE (high-density polyethylene). The pumping stations are equipped (depending on the selected model) with discharge pipelines with shut-off and non-return valves, a tight transition through the walls of the gravity and discharge pipelines, and an optional additional control system. Ball check valves installed on the discharge risers prevent wastewater backflow, while shut-off valves allow for shut-off for maintenance purposes. LIQUID LEVEL CONTROL

3. In the basic version of the pumping station, the following wastewater levels are used in the control system: - Maximum level - pump activation, - Minimum level - pump deactivation. Accessories such as the SAFEMATIC electronic pump protection, the E1/E2 Set control box for electric pumps, and the Pedrollo EP electronic pump protection can be ordered for this pumping station.

IMPORTANT! Upon receipt of the goods, the Buyer is obligated to inspect the goods for quality and quantity and to report any concerns regarding the goods visible on the day of delivery, under penalty of forfeiture of subsequent warranty claims. If the goods are delivered by an external courier company, the Buyer should inspect the goods and immediately report any damage to the carrier before delivery. If, after delivery, the Buyer discovers any loss or damage to the goods that was not visible from the outside upon receipt, they should report this to the carrier and the Seller immediately after discovering the damage, but no later than 7 days from the date of delivery.